Shop Cor-A-Vent
1 - 1 of 1 results for Cor-A-Vent
- Browse and order high-grade Cor-A-Vent essentials for your property renovations at Arlington Coal and Lumber. Understanding Cor-A-Vent product lines enables buyers to select effective components that optimize attic air circulation. Categorized under Roof Underlayment products, these specialized supplies support balanced roof ventilation and prevent premature shingle deterioration. Highlighted offerings feature the revolution 20-ft rolled ridge vent by cor-a-vent - incl's 2 coils 1-3/4-in roof nails peel & stick end caps - recognized for its durability and complete installation kit inclusion. We are your best partner in bringing your dream project to life by providing best material estimates with our friendly locations close to you from Arlington Coal and Lumber Company, Burlington Lumber Company, Wilmington Builders Supply, Sudbury Lumber Company, Chelmsford Lumber Company, and Hudson Lumber Company. Check out our products page or contact us to start planning your venture across the Greater Boston, Massachusetts, New Hampshire, and surrounding New England region.
Cor-A-Vent serve as critical ventilation channels rather than drywall panels, ensuring proper airflow dynamics throughout your roofing system. While drywall requires distinct interior finishing materials, Cor-A-Vent products are engineered specifically to work alongside roof underlayment and structural decking. By creating a continuous exhaust path along the ridge, these panels exhaust trapped attic heat and moisture before condensation can compromise structural framing or insulation values. Integrating Cor-A-Vent with your underlayment layer establishes a balanced intake and exhaust ecosystem, safeguarding your entire building envelope from mold growth, ice dam formation, and premature shingle thermal cracking.
Buyers Guide: To ensure maximum defense and warranty compliance on your next build, review these frequently asked questions regarding Cor-A-Vent and roof underlayment selection and installation practices.- Does the vent compress under shingles or fasteners? No, Cor-A-Vent products utilize rigid, high-density polymer matrices designed to withstand the heavy clamping force of cap shingles and pneumatic nail guns without crushing the internal air channels.
- What roof pitch is required? These ridge vents are typically designed to function effectively on roof pitches ranging from a standard 3:12 slope up to a steep 16:12 pitch.
- Does a ridge vent need to be covered? Yes, ridge vents must always be capped with matching hip and ridge accessory shingles to shield the plastic core from direct ultraviolet exposure and complete the architectural aesthetic.
- How much Net Free Vent Area (NFVA) does it give? The exact Net Free Vent Area varies by specific profile, but standard Cor-A-Vent rolls typically deliver between 10 to 20 square inches of venting area per lineal foot, ensuring ample exhaust capacity.
- How does it stop weather and insects? Built-in, fine-mesh scrim barriers block driving rain, snow, and stinging insects like wasps and bees from entering the attic cavity while maintaining uninhibited airflow.
- Can it be used for Above-Sheathing Ventilation (ASV)? Yes, specialized Cor-A-Vent configurations work exceptionally well for Above-Sheathing Ventilation over metal, tile, or shingle roofs, helping dissipate radiant heat loads and lower home cooling costs.
- What comes included in the Revolution Roll kit? The complete kit typically packs a 20-ft rolled ridge vent, two full coils of 1-3/4-in roofing nails, and pre-formed peel-and-stick end caps for a turnkey installation.
- Can it be installed by a single person? Yes, lightweight rolled designs allow a single contractor or DIY homeowner to easily unroll, align, and fasten the vent along the ridge line without requiring extra labor assistance.
- How do you cut the ridge slot before installation? You must leave a continuous slot open along the roof peak - typically 1 to 2 inches wide total - by cutting back the plywood or OSB decking on both sides of the ridge board.
- Are specialized fasteners required for installation? You should use the corrosion-resistant 1-3/4-in roofing nails included in the kit to penetrate deeply through the vent and roof sheathing into the underlying rafters.
- Will installing a ridge vent lower my energy bills? Yes, by continuously venting hot attic air during summer months, it reduces the load on your air conditioning system and improves overall home energy efficiency.
- Can Cor-A-Vent be painted or stained? These polymer components are colored throughout to blend seamlessly with dark shingle tones and generally do not require painting, maintaining their appearance over decades of exposure.
- How does it handle freeze-thaw cycles? Engineered with heavy-duty exterior polymers, Cor-A-Vent resists cracking and warping even under extreme sub-zero winter temperatures and severe frost heaves.
- Does it work with all shingle brands? Yes, Cor-A-Vent is fully compatible with architectural and 3-tab asphalt shingles from leading manufacturers, providing a clean, low-profile finish across the roof peak.
- Is a ridge vent better than box vents or gable louvers? Ridge vents provide superior, balanced exhaust airflow across the entire attic space by utilizing natural thermal buoyancy, eliminating the dead zones common with static box vents.
Popular Ideas and Applications for Cor-A-Vent and Roof Underlayment:- Continuous ridge exhaust integration: Pairing a high-performance rolled ridge vent directly over synthetic roof underlayment ensures maximum thermal airflow, preventing attic heat buildup and extending the lifespan of asphalt shingles in humid climates.
- Vaulted ceiling condensation defense: Installing Cor-A-Vent over unvented cathedral ceilings allows trapped indoor moisture to escape outward, protecting structural rafters from dry rot and structural warping.
- Metal roofing ventilation upgrade: Utilizing specialized high-temperature Cor-A-Vent strips beneath standing seam metal panels provides essential Above-Sheathing Ventilation, reducing radiant heat transfer into living spaces during peak summer months.
- Complex architectural roof lines: Implementing continuous ridge venting on multi-gable custom homes helps balance intake and exhaust pressures across intersecting roof planes where static box vents cannot fit.
- All-in-one kit efficiency on job sites: Contractors working on tight construction schedules rely on complete kits containing rolls, nails, and end caps to speed up dry-in phases and maintain strict building code compliance.
You can also create an account online to streamline your ordering process, track order histories, and manage material deliveries efficiently, or check out all product categories to source every specialized supply required for your next build. - Does the vent compress under shingles or fasteners? No, Cor-A-Vent products utilize rigid, high-density polymer matrices designed to withstand the heavy clamping force of cap shingles and pneumatic nail guns without crushing the internal air channels.
Pack Quantity
The quantity that makes up a standard package.
You must order in units of this quantity.
Items are sold in Gross and Pieces.
Example: Package quantity
- .3333 gross enter .3333
- 10 gross enter 10 or 20, 30 etc.
- 72 pieces enter 72 or 144, 216 etc.
Please note: 1 gross = 144 pieces.
| Pack Quantity | Pieces |
|---|---|
| 0.0208 | 3 |
| 0.0417 | 6 |
| 0.0555 | 8 |
| 0.0625 | 9 |
| 0.0694 | 10 |
| 0.0833 | 12 |
| 0.1041 | 15 |
| 0.1111 | 16 |
| 0.1250 | 18 |
| 0.1389 | 20 |
| 0.1667 | 24 |
| 0.2083 | 30 |
| 0.2222 | 32 |
| 0.2500 | 36 |
| 0.2778 | 40 |
| 0.3333 | 48 |
| 0.4166 | 60 |
| 0.5000 | 72 |
| 0.6667 | 96 |
| 0.7500 | 108 |
| 1.3333 | 192 |
| 1.5000 | 216 |
| 1.6667 | 240 |